Led high pole lamp maintenance is complex in terms of safety and technical difficulty. Therefore, each project has specialized management and maintenance for road lighting. These technicians are specially trained and proficient in the safe operation of high pole streetlights, as well as the maintenance techniques for motors, worm gears, and worm screws. Establishing a professional team for led high pole lamp maintenance is beneficial for the institutional management of high pole lamps and can effectively improve the safety and efficiency of maintenance.
When performing maintenance on led high pole lamp equipment, careful inspections should be conducted on the parts of the led high pole lamp working system. When repairing, temporary power supply lines should connect to the power plug of the lamp panel to power it on. For safety reasons, it is advisable to add a protective device to prevent electric shock if necessary.
Regular maintenance and care of led high pole lamps include:
1. During the winding and unwinding of the steel cable, check the appearance of the cable and observe for overlaps, twists, rust, broken strands, and signs of severe stress. Inspect all sliding parts to ensure they are flexible and reliable.
2. The motor, gearbox, and other drive mechanisms fixed at the bottom of the lamp pole should be covered as much as possible to prevent moisture from damaging the insulation. Check that there is enough oil in the gearbox and that the oil is not black or contaminated. Movable motor drive mechanisms should be placed in a dry area, and their insulation resistance must be tested with a megohmmeter before use (should not be less than 1 MΩ).
3. Replace damaged light source equipment, cables, and check all fixed bolts for looseness, firmness, and reliability. Replace any severely rusted components as necessary.
4. The grounding protection device and lightning protection device of the led high pole lamp lighting equipment should be routinely checked before the rainy season every year, testing the grounding resistance. If the grounding resistance does not meet the required value (should be less than 10 Ω), it should be addressed promptly.
5. The AC contactors, thermal relays, limit switches, and control devices in the control circuit of the high pole lamp should be thoroughly inspected before operation. Any faulty electrical components should be replaced quickly, and operating with faulty equipment is strictly prohibited.
All inspection and maintenance records should be documented. After completing the maintenance work, the electrical parts of the high pole lighting facility and the lifting drive mechanism should be inspected again. Only after confirming everything is correct can the lamp panel be raised and hung to ensure responsible maintenance.
The led high pole lamp manufacturer specializes in research, development, production, and sales of outdoor lighting products. If you wish to purchase led high pole lamps, please contact us for quality assurance and 5-year after-sales service. We welcome you to call and place your order!